Installation

Physical installation, antenna setup, and initial startup for Haltian Gateway XS

Before You Begin

Choose a Backhaul

Gateway XS uses either cellular or wired LAN for its cloud connection. Choose the backhaul and confirm its requirements before installation and mounting.

  • Cellular (standard deployment): Haltian pre-configures the SIM and connectivity. Confirm LTE coverage at the installation site.
  • Wired LAN (customer-specific deployment): Confirm availability and approved network settings with Haltian before installation. Haltian delivers a unique console password for each gateway to the customer during the delivery phase; have the password for this gateway before setup. Configure Ethernet after power-up using the LAN Setup Console guide.

Package Contents

Verify you have received all components:

  • Haltian Gateway XS unit
  • 12V DC power supply
  • Wall mount bracket
  • Cellular antenna (SMA connector)
  • 2.4 GHz radio antenna (SMA connector)

Additional Requirements

You will need:

  • Power outlet: Standard AC outlet appropriate for your region
  • Network access: LTE coverage for cellular deployments, or an approved Ethernet connection and customer network details for LAN deployments
  • Tools: Screwdriver for mounting (if required)

Cellular Connectivity

For the standard cellular deployment, Haltian configures the SIM and connectivity before delivery. The gateway connects automatically after power-on; no SIM installation or network configuration is required.

Antenna Installation

Install both antennas before powering on the gateway.

Cellular Antenna

  1. Identify the cellular antenna port (labeled on the gateway housing)
  2. Align the SMA connector straight with the port — do not insert at an angle
  3. Turn the connector clockwise by hand until finger-tight
  4. Do not over-tighten — finger-tight is sufficient for a secure connection

2.4 GHz Radio Antenna

  1. Identify the 2.4 GHz antenna port (labeled on the gateway housing)
  2. Align the SMA connector straight with the port
  3. Turn the connector clockwise by hand until finger-tight
  4. Verify the antenna is stable and does not wobble

Power Connection

12V DC Power Setup

  1. Connect power cable to gateway

    • Connect the power cable to the gateway’s terminal block
    • Ensure the connection is secure
  2. Connect to power outlet

    • Plug the power supply into an AC outlet
    • The gateway begins its boot sequence automatically

Power Requirements

ParameterSpecification
Voltage12V DC
Power supplyIncluded external adapter

Physical Installation

Gateway XS is delivered with a wall mount bracket. Mount the gateway on a wall or other flat surface indoors, leaving clearance around the device for airflow.

Placement Considerations

  • Temperature: Ensure ambient temperature stays between 0°C and +40°C
  • Ventilation: Allow clearance around the unit for airflow
  • Antennas: Position antennas vertically for best signal when possible
  • Avoid: Direct sunlight, moisture, excessive vibration

Initial Startup

Boot Sequence

After connecting power, the gateway boots automatically. The initial startup takes approximately 60–90 seconds.

Verify Network Connection

The gateway establishes a network connection automatically after boot:

  • Cellular (LTE): Connects automatically using connectivity pre-configured by Haltian — no customer action required
  • Wired LAN: Connect the gateway to the approved customer network and configure Ethernet using the LAN Setup Console

To verify the connection is established:

  1. Wait 2–3 minutes after power-on for the gateway to complete boot and network registration
  2. Log in to Haltian Studio
  3. Navigate to Devices → Gateways
  4. Locate the gateway by UUID
  5. Verify:
    • Status: Online
    • Last Seen: Recent timestamp (within 1–2 minutes)
    • Cellular Connection: Active (if using LTE)

Status LEDs

The gateway has two status LEDs:

  • Green (left): MQTT connection
  • Amber (right): Cellular network

For cellular deployments, a healthy state is green solid on and amber off. When cellular is not configured, a brief amber flash every 10 seconds can be expected if no SIM is detected.

Green LED: MQTT connection

PatternMeaning
Solid onPrimary MQTT connection is active.
Slow blink (about once per second)Secondary MQTT connection is active.
Fast blink (several times per second)A network connection is available, but neither MQTT connection is active yet. This may be transient while the connection establishes. If it persists, check the MQTT configuration.
OffNo network connection is available. Check the Ethernet cable and/or cellular antenna and SIM.

Amber LED: Cellular network

PatternMeaning
OffRegistered on the cellular network. This is normal.
Slow blink (about once per second)Searching for a cellular network. This usually resolves within a minute or two.
Brief flash every 10 seconds (about 1 second on)No SIM card detected. This is expected when the device is not configured for cellular. If a SIM should be installed, check that it is inserted correctly.
Solid onCellular registration problem, such as a SIM/account issue or network rejection. Check the SIM and antenna connection. If it persists, contact the operator or Haltian support.

Sensor Deployment

After gateway installation:

  1. Position sensors within range of the Wirepas Mesh network (up to 25 m per hop indoors)
  2. Power on the sensors — they join the configured Wirepas Mesh network automatically
  3. Verify that the sensors appear in Haltian Studio and begin reporting data
  4. Allow 15–30 minutes for the mesh network to form and stabilize

No manual sensor-to-gateway assignment is required. In deployments with multiple gateways, Wirepas routes sensor messages to an available gateway sink.

Post-Installation Checklist

After initial startup, verify:

  • Antennas securely connected (no wobble, finger-tight)
  • Power supply connected and stable
  • Gateway appears online in Haltian Studio
  • Signal quality acceptable (if cellular)
  • Gateway named appropriately in Studio
  • Firmware version verified in Haltian Studio
  • Physical mounting is secure